JMP/CFM56/D/4777/C600
.
This rig is all as per our rig JMP/CFM56/D/4777/C200 but for the following:
MODIFICATIONS:
• Actuated ball valves replace the existing manual outlet ball valves for remote operation.
• Remote control with 50m cable complete with Harting fitting for connection to rig (SM903).
• 380/440V, 3 phase, 50Hz electrical heating system incorporating control circuit for remote operation.
• Accessory Air Inlet Kit incorporated (JMP/CFM56/D/6612).
• Chassis mounted brackets either side of the rig for external housing of the wash probes.