JMP/CFM56/D/4777/C601
.
This rig is as per JMP/CFM56/D/4777/C200 but for the following:
MODIFICATIONS:
• Actuated ball valves replace the existing manual outlet ball valves for remote operation.
• Remote control with 50m cable complete with Harting fitting for connection to rig (SM903).
• 380/440V, 3 phase, 50hz electrical heating system incorporating control circuit for remote operation.
• Accessory Air Inlet Kit incorporated (JMP/CFM56/D/6612) complete with quick release Stäubli socket and plug (SM947).
• Operating instructions and decal set in French.
• Set of LEAP-1A engine wash probes (JMP/LEAP/D/7028).
• Chassis mounted brackets either side of rig for external wash probe housing.